Home › Heat treatment simulation
Heat treatment · Simulation
Heat treatment simulation: see the furnace, the heating and the quench before the part goes in.
Choose the part and the material, enter the furnace program: the gas flow and temperature distribution inside the furnace, when the surface and the core of the part enter the band, and the estimated hardness and martensite fraction after quenching are calculated. Runs in the browser, nothing to install.
- Gas flow and temperature distribution in the furnace
- Part heating and time in band
- Quench: estimated hardness and martensite
- TUS history and furnace model

Furnace and part
When does the part heat up in the furnace, and what hardness do you get?
The furnace reaching its set point does not mean the part is hot: in a large section the core lags behind the surface, not every corner of the furnace has the same temperature, and in the quench the surface and the core harden differently. The simulation estimates these in advance; the result is confirmed by measurement.
1. See the furnace
The furnace model or the detailed flow, heat and radiation calculation estimates the temperature distribution inside the furnace. If you have measured TUS readings, the distribution is taken from them; measurement comes first.
2. See the heating
Time for the surface and the core to enter the band, time the whole part stays in the band, and the surface–core difference. Load mass and furnace power are included.
3. See the quench
Cooling according to the quenchant, agitation and transfer time; estimated hardness, martensite fraction and zones at risk of cracking and distortion.
Screen by screen
Get to know the heat treatment simulator
The images below are taken from the application itself (Turkish interface; the simulator is also available in English, Arabic, German and Azerbaijani). The numbers mark parts of the screen; the explanations are below each image.
1. Gas flow and temperature in the furnace (detailed calculation)
Electric furnace with fan, gas from top to bottom: flow, heat and radiation are calculated together.

- 1Calculation mesh and the option to heat from a cold furnace.
- 2Run the detailed calculation.
- 3Calculation summary: number of cells, convergence, energy balance.
- 4Heating curve of the furnace.
- 5Furnace distribution tab.
- 6Virtual thermocouples; the coldest and the hottest point.
- 7Gas flow lines.
- 8Colour scale: deviation from the set point.
- 9Play the gas flow.
2. Furnace heat-up
Heating from a cold furnace to the set point, played over time.

- 1Also calculate the furnace heat-up.
- 2Hottest and coldest point at that moment.
- 3Colour scale: thermocouple readings at that moment.
- 4Heating curve of the furnace.
- 5Time slider.
3. Estimated distribution with the furnace model
Estimated temperature distribution from furnace size, type and gas flow direction; measured TUS comes first.

- 1Source of the distribution: furnace model, thermocouple readings or TUS record.
- 2Furnace type, gas flow direction, gas velocity, insulation.
- 3Control thermocouple and its oscillation.
- 4Calculate the distribution with the furnace model.
- 5Description and limits of the model.
- 6Virtual thermocouples and the part position.
- 7Colour scale.
- 8Note on screen: it does not replace a measured TUS.
4. TUS history: where is the furnace changing?
Four TUS tests of the same furnace compared: which zone is getting colder over time?

- 1Furnace name and TUS date.
- 2Saved tests: lowest and highest reading.
- 3Compare.
- 4Change and trend by zone (°C/month).
- 5The corner that changes most, in 3D.
- 6Colour scale: difference between the last and the first test.
- 7The zone that got worst.
5. Part heating
Ø120 mm shaft, quarter section at minute 12: the surface is hot, the core lags behind.

- 1Result tabs: heating, time in band, quench, hardness, martensite, crack and distortion risk, t8/5.
- 2Heating curves: furnace, surface, core.
- 3Quench curves: surface and core.
- 4Method and references.
- 53D temperature field.
- 6Play over time.
- 7Estimated hardness: surface / core.
- 8Heating and soak times.
- 9Quench summary.
6. Estimated hardness after quenching
Oil quench: hard surface, softer core.

- 1Estimated hardness tab.
- 2Hardness map (quarter section).
- 3Colour scale.
- 4Surface and core hardness.
- 5Quench curves.
- 6Quench summary: quenchant, temperature entering the quench, Ms, t8/5.
7. Estimated martensite fraction
Martensite fraction in the same quench: high at the surface, low in the core.

- 1Estimated martensite tab.
- 2Martensite map.
- 3Colour scale.
- 4Surface and core martensite fraction.
- 5Number of cells at risk of cracking and distortion.
8. Engineering: rough Jominy curve from the composition
Rough Jominy curve from the material composition; can be used in the hardness calculation if you wish.

- 1Estimated hardness at the Jominy distances.
- 2Jominy curve.
- 3Note on screen: rough estimate; a tested Jominy curve comes first.
- 4Use this curve in the hardness calculation.
What can you do?
Furnace, heating, quench and report
Too short a soak, hardness that is not met or a cracked part means re-treatment, scrap and late delivery. The simulation lets you try the program, the load and the quenchant on screen before the part goes into the furnace.
Part and fixture
Shaft, tube, block or STEP/IGES; part and fixture (basket, hanger, support) from the NTB SpecPro 3D CAD screen.
Material
Alloy steels, martensitic and precipitation-hardening stainless, tool steel, maraging, nickel alloy, aluminium and titanium; your own composition.
Furnace and program
Atmosphere (with or without fan), vacuum, salt bath; ramp–soak program; comparison with the furnace record (CSV).
Load
Total mass, arrangement and furnace power: if the power is not enough, the furnace temperature drops and heating takes longer.
Gas flow in the furnace
Detailed flow, heat and radiation calculation; heating from a cold furnace and gas flow animation.
TUS distribution and history
Distribution from thermocouple readings, SAT difference, comparison of tests of the same furnace and the zone that is getting worse. Distribution from a TUS Excel/CSV record: 1 ntb (1 ntb = 10 TL + VAT, 12 TL including VAT).
Quench
Water, brine, polymer, oil, salt bath, nitrogen and helium, air or your own quenchant values; quenchant heating.
Results
Estimated hardness and martensite map, t8/5, crack and distortion risk, cooling rate in the critical range for aluminium; tempering and ageing.
Engineering calculations
Rough Jominy curve from the composition, case depth and carburizing time, carbon diffusion, hardness conversion, load energy and cost.
PDF report
Cycle report with section maps.
How does it work?
Heat treatment simulation in four steps
Part and material
Choose the part or load a STEP file; choose the material.
Furnace and program
Enter the furnace type, the ramp–soak program and the load; choose the distribution.
Quench
Choose the quenchant, the agitation and the transfer time.
Result and report
Heating, time in band, estimated hardness and martensite, risk zones; PDF report.
All values are estimates; the program does not decide, part approval is given by measurement. Heating and quenching are calculated with finite volume heat conduction; quenchant and furnace heat transfer coefficients are typical literature values, the real quenchant and furnace may differ. A STEP part is calculated with cubic cells; thin sections stay coarse. Transformation temperatures are estimated with Andrews (1965), martensite fraction with Koistinen–Marburger (1959), tempering with Hollomon–Jaffe (1945); hardness from the Jominy values you enter or with Yurioka et al. (1987). Bainite and pearlite fractions are not calculated separately. In the furnace model the furnace is a box; fan, shelves and basket are simplified, and the flame is not modelled in a gas-fired furnace. The estimated distribution does not replace a measured TUS; measurement always comes first. Values between thermocouple points are interpolated. The calculations are checked in automated tests; a comparison with real furnace and quenchant measurements has not been made yet.
Heat treatment module
Simulation on the computer, in the browser
The heat treatment simulator is part of the Heat treatment module; there is no extra charge for each calculation or simulation. Only reading the distribution from a TUS Excel/CSV record uses 1 ntb (1 ntb = 10 TL + VAT, 12 TL including VAT).
- The simulations run on the computer, in the browser
- 7 days free when you open an account
- Included in the Heat treatment module, no charge per calculation
Other simulations
Weld distortion, press brake and CNC simulations.
Weld distortion simulation →
Press brake simulation →
CNC simulation →
Frequently asked questions
What does the heat treatment simulation do?
Before the part goes into the furnace, it shows the temperature distribution inside the furnace, when the surface and the core of the part enter the band, the estimated hardness and martensite fraction after quenching, and the zones at risk of cracking and distortion. The program, the load and the quenchant are tried on screen; the result is confirmed by measurement.
How does it show the temperature distribution inside the furnace?
There are three ways: a distribution from measured TUS thermocouple readings; an estimated distribution from the furnace size, type and gas flow direction; and a detailed flow, heat and radiation calculation. The estimated distribution does not replace a measured TUS.
Which materials are included?
Alloy steels (C45, 42CrMo4, 34CrNiMo6, 100Cr6 and others, or your own composition), martensitic and precipitation-hardening stainless steels, H13 and D2 tool steels, Maraging 300, 718 nickel alloy (UNS N07718), aluminium alloys and Ti-6Al-4V.
How accurate are the results?
All values are estimates; the program does not decide, part approval is given by measurement. Heating and quenching are calculated with finite volume heat conduction; quenchant and furnace heat transfer coefficients are typical literature values, the real quenchant and furnace may differ. A STEP part is calculated with cubic cells; thin sections stay coarse. Transformation temperatures are estimated with Andrews (1965), martensite fraction with Koistinen–Marburger (1959), tempering with Hollomon–Jaffe (1945); hardness from the Jominy values you enter or with Yurioka et al. (1987). Bainite and pearlite fractions are not calculated separately. In the furnace model the furnace is a box; fan, shelves and basket are simplified, and the flame is not modelled in a gas-fired furnace. The estimated distribution does not replace a measured TUS; measurement always comes first. Values between thermocouple points are interpolated. The calculations are checked in automated tests; a comparison with real furnace and quenchant measurements has not been made yet.
Does it work on the phone?
No. The simulation runs on the computer, in the browser; nothing to install.
What does it cost?
The heat treatment simulation is included in the Heat treatment module; there is no extra charge for each calculation or simulation. Only reading the distribution from a TUS Excel/CSV record uses 1 ntb (1 ntb = 10 TL + VAT, 12 TL including VAT). You can try it free for 7 days when you open an account. The module price is in the price table.